  • $274.00


The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. 

Features

  • VoltAlert™ technology for non-contact voltage detection
  • AutoVolt automatic ac/dc voltage selection
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • True-rms for accurate measurements on non-linear loads
  • Measures 10 A (20 A overload for 30-seconds)
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
  • CAT III 600 V safety rated
Specifications
Maximum voltage between any terminal and earth ground 600V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 °C to + 50 °C
Storage Temperature -40 °C to + 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range: 600.0 mV
Resolution: 0.1
mVAccuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution: 6.000 V / 0.001 VRange/Resolution: 60.00 V / 0.01 VRange/Resolution: 600.00 V / 0.1 VAccuracy: ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivoltstrue-rms Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC voltstrue-rms Range/Resolution: 6.000 V / 0.001 VRange/Resolution: 60.00 V / 0.01 VRange/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz); 2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω;
detects opens or shorts of 500 μs or longer.
Ohms Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 5 % + 2
Diode Test Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance Range/Resolution: 600.0 Ω / 0.1Ω
Range/Resolution: 6.000 kΩ / 0.001kΩ
Range/Resolution: 60.00 kΩ / 0.01kΩ
Range/Resolution: 600.0 kΩ / 0.1kΩ
Range/Resolution: 6.000 MΩ / 0.001MΩ
Accuracy: 0.9 % + 1

Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 5 % + 2
LoZ capacitance Range: 1 nF to 500 μF
Accuracy: 10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz) Range/Resolution: 6.000 A / 0.001 ARange/Resolution: 10.00 A / 0.01 A

Accuracy: 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps Range/Resolution: 6.000 A / 0.001A
Range/Resolution: 10.00 A / 0.01 A

Accuracy: 1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)2 Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.99 Hz / 0.1 Hz
Range/Resolution: 9.999 Hz / 0.001 Hz
Range/Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2