IR Thermometer with K-type thermocouple

Fluke
  • $309.00


Lighten up your toolbox. The Fluke 56x (series of  IR and contact thermometers), combines the temperature measurement functions that industrial, electrical, and HVAC/R professionals need, all in one tool. It measures both infrared and contact temperature, replacing several other test tools. It’s fast, efficient, and easy to use, saving you valuable time and effort.
 
The Fluke 561, 566 and 568 Infrared Thermometers are for non-contact temperature measurement. These thermometers determine an object’s surface temperature by measuring the amount of infrared energy radiated by the object’s surface. The thermometers also support contacttemperature measurement via K-type thermocouple.
With the Fluke 56x infrared thermometer, you can also take contact and ambient temperatures in the way that’s best for you. Use the IR thermometer to measure hot, moving, electrically energized, and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor-leave your ladder in the truck. You can use the Fluke 56x’s handy flexible pipe probe, or plug in any industry standard type K mini connector thermocouple probe you already own to take super-heat or internal temperatures.

features 

  • IR thermometer for quick measurements up close, or at a distance, without a ladder
  • Contact thermometry capability, compatible with all standard mini-connector type K thermocouples, preserves your investment in thermocouples
  • Fabric hook-and-loop fastener pipe probe for superheat and sub-cooling and other contact and ambient measurements
  • Single-point laser sighting
  • Temperature range of -40°C to 550° C (-40°F to 1022°F) covers most industrial and residential applications
  • Easy emissivity adjustment (Lo, Med, Hi) for measuring pipes and other shiny materials more accurately
  • Lightweight (just 12 ounces / 340 grams) and portable
  • Efficient – no need to shut down equipment when making IR measurements
  • MIN, MAX, and DIF functions help you quickly identify problems
  • Scan large areas or small objects quickly and efficiently

specifications

  Fluke 561 Fluke 566 Fluke 568
IR Temperature Range -40 °C to 550 °C (-40 °F to 1022 °F) -40 °C to 650 °C (-40 °F to 1202 °F) -40 °C to 800 °C (-40 °F to 1472 °F)
Accuracy <0 °C: ±(1.0 °C + 0.1 °/1 °C)
>0 °C: ±1 % or ± 1.0 °C, whichever is greater (<32 F±2 °F ±0.1 °/1 °F)
>32 °F: ±1 % or ±2 °F), whichever is greater
Repeatability ±0.5 % of reading or ±1 °C (2 °F), whichever is greater. ±0.5 % of reading or ±0.5 °C (1 °F), whichever is greater.
Display Resolution 0.1 °C / 0.1 °F 0.1 °C / 0.1 °F 0.1 °C / 0.1 °F
Spectral Response 8 to 14 μm 8 to 14 μm 8 to 14 μm
Response Time (95 %) <500 ms <500 ms <500 ms
K-Type Thermocouple Input Temperature Range 0 °C to 100 °C
(32 °F to 212 °F)
-270 °C to 1372 °C (-454 °F to 2501 °F)
K-Type Thermocouple Input Accuracy Input accuracy ±2.2 °C (±4 °F) -270 °C to -40 °C: ±(1 °C + 0.2 °/1 °C)
(-454 °F to -40 °F: ±(2 °F + 0.2 °/1 °F))
-40 °C to 1372 °C: ±1 % or 1 °C (-40 °F to 2501 °F: ±1 % or 2 °F), whichever is greater
K-Type Thermocouple Resolution 0.1 °C (0.1 °F) 0.1 °C (0.1 °F) 0.1 °C (0.1 °F)
Distance:Spot (90 % energy) 12:1 30:1 50:1
Laser sighting Single laser, output <1 mW Class II, wavelength 630 to 670 nm
Emissivity Lo, Med, Hi Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Relative Humidity 10 % to 90 % RH non-condensing up to 30 °C (86 °F)
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Power 2 AA /LR6 Batteries (alkaline or NiCD) 2 AA /LR6 Batteries or USB connection when used with a PC