Menu
Cart 0
Milliamp Process Clamp Meters

Milliamp Process Clamp Meters

Fluke
  • $822.00


general specifications:

  • Best in class 0.2% accuracy
  • Diameter of measurable conductor: 0.177 in or 4.5 mm max
  • Operating temperature: -10 to 50°C
  • Operating humidity: < 90% @ < 30°C, < 75% @ 30 to 55°C
  • Operating altitude: 0 to 2000 m
  • IP rating: IP 40
  • Vibration: Random 2 g, 5 to 500 Hz
  • Shock: 1 m drop test (except the jaw)
  • EMI/RFI: Meets EN61326-1 (For current measurement w/ JAW, add 1 mA to specification for EMC field strengths of 1 V/m up to 3 V/m.)
  • Temperature coefficient: 0.01% °C (< 18°C or > 28°C)
  • Power, battery life: (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical
  • Warranty: Three years for electronics 
  • One year for cable and clamp assembly

mA measurement 
(measured by clamp)

 

 

Resolution / range

 

 

0 to 20.99 mA

 

 

FLUKE771
FLUKE772,  FLUKE773

 

 

Accuracy

 

 

0.2% + 5 counts

 

 

Resolution / range

 

 

21.0mA to 100.0 mA

 

 

Accuracy

 

 

1% + 5 counts

 

 

mA measurement (measured in series with test jacks)

 

 

Resolution / range

 

 

0 to 24.00 mA

 

 

FLUKE772, FLUKE773

 

 

Accuracy

 

 

0.2% + 2 counts

 

 

mA source
(maximum mA drive: 24 mA into 1,000 ohms)

 

 

Resolution / range

 

 

0 to 24.00 mA

 

 

Accuracy

 

 

0.2% + 2 counts

 

 

mA simulate
(maximum voltage 50 V dc)

 

 

Resolution / range

 

 

0 to 24.00 mA

 

 

Accuracy

 

 

0.2% + 2 counts

 

 

Voltage source
 (2 mA maximum drive current)

 

 

Resolution / range

 

 

0 to 10.00 V DC

 

 

FLUKE773 only


We Also Recommend
...