Menu
Cart 0

Motor Rotation Tester

REED
  • $119.00


This REED R5004 Phase Sequence/Motor Rotation Tester is highly accurate and has an extremely fast response, great features that recommend it as a versatile tester when you need to check a motor's rotation direction without any contact.

More info

REED R5004 Features

  • Tests phase orientation of 3-phase power sources
  • Indicates phase orientation (clockwise or counter-clockwise and whether each of the
    three phases is live)
  • Also indicates direction of motor rotation
  • Determines motor rotation without contact
  • Easy to open alligator clips with wide jaws
  • Double molded housing
  • Cat. III 600V safety rating
  • Complete with cables with 3 colour-coded alligator clips, 9V battery and carrying case

REED R5004 Specifications

  • Input Voltage: 40 to 600 VAC
  • Operating Frequency: 2 to 400 Hz
  • Power Supply: 9V alkaline battery
  • Dimensions: 5.0 x 2.7 x 1.2" (128 x 68 x 30mm)
  • Weight: 6.5 oz (185g)

How to use Reed Motor Rotation Tester (R5004)

Determining the Rotary Field Direction

Make sure the L1,L2, and L3 test leads are connected to the corresponding input jacks. Connect the test probes to the other end of the test leads. Connect the test probes to the three main phases. Press the ON/OFF button. The green ON indicator shows that the instrument is ready for testing. Either the Clockwise or Counter Clockwise Rotary indicator will illuminate showing the type of rotary field direction present. The rotary indicator will light up even if the neutral conductor, N, is connected instead of the test lead input jack. See Phase Indication Table for more information (User manual).

Determining the Motor Connection
Connect one end of the test leads to the unit and the alligator clamps to the other end of the test leads. Connect the alligator clamps to the motor connections.Press the ON/OFF button. The green ON indicator shows that the instrument is ready for testing. Turn the motor shaft half a revolution towards the right. The bottom of this unit should be oriented towards the drive shaft. Either the Clockwise or Counter Clockwise Rotary indicator will illuminate showing the type of rotary field direction present.

Non-contact Rotary Field Indication
Put the Motor Rotation Tester on the motor so that it is parallel to the length of the motor shaft. The unit should be one inch or closer to the motor, and the bottom of the unit should be oriented towards the drive shaft. Press the ON/OFF button. The green ON indicator shows that the instrument is ready for testing. Either the Clockwise or Counter Clockwise Rotary indicator will illuminate showing the type of rotary field direction present.

Magnetic Field Detection
To detect a magnetic field, place this unit to a solenoid valve. A magnetic field is present if either the Clockwise or the Counter Clockwise Rotary indicator illuminates.

 


We Also Recommend